firelite ann 80 user manual

Welcome to the FireLite ANN-80 User Manual, your comprehensive guide to understanding and utilizing the ANN-80 Series Remote Fire Annunciators. Designed for use with compatible Fire Alarm Control Panels (FACPs), this compact, backlit LCD display provides real-time system status, including device type, zone information, alarms, trouble, or supervisory conditions. Perfect for monitoring zones, points, and custom messages, the ANN-80 enhances fire safety management with clear, English-language text. This manual covers installation, programming, operation, and maintenance to ensure optimal performance.

Overview of the FireLite ANN-80 Series

The FireLite ANN-80 Series includes compact, backlit LCD annunciators designed for use with compatible Fire Alarm Control Panels (FACPs). Models such as the ANN-80, ANN-80-W, and ANN-80C offer a clear, 80-character display, mimicking the FACP’s interface. These units provide real-time status updates, including device types, zone alarms, trouble conditions, and custom messages. Their compact design and English-language text capability make them ideal for monitoring fire safety systems in various applications, ensuring ease of use and reliable performance.

Key Features and Benefits

The FireLite ANN-80 Series offers a range of features, including an 80-character backlit LCD display, English-language text for clarity, and compatibility with multiple Fire-Lite FACPs. It provides independent point and zone monitoring, displaying device types, alarms, trouble, and supervisory states. The compact design allows for flexible installation, and the serial interface with ANN-Bus simplifies connectivity. These features ensure enhanced system monitoring, making the ANN-80 Series an efficient and reliable solution for fire safety management and control;

System Requirements and Compatibility

The FireLite ANN-80 Series is compatible with multiple Fire-Lite FACPs and operates within an 18-28 VCC power range, ensuring seamless integration into existing fire alarm systems.

Compatible Fire Alarm Control Panels (FACPs)

The FireLite ANN-80 Series is designed to work seamlessly with various Fire-Lite FACPs, including the MS-9200UDLS and other compatible models. This ensures the annunciator integrates smoothly into your existing fire alarm system, providing consistent and reliable monitoring. Compatibility is key to maintaining system integrity and functionality. Always refer to the FACP manual for specific pairing recommendations to ensure optimal performance.

Electrical Requirements

The FireLite ANN-80 Series operates on a nominal input range of 18-28 VDC, with a maximum current draw of 40mA. Ensure a stable power supply to maintain proper functionality. The annunciator requires no additional power for backlighting, as it is powered directly through the FACPs. Always verify power specifications before installation to prevent malfunctions. Refer to the FACP manual for detailed wiring instructions to ensure compatibility and safe operation.

Installation Guidelines

Ensure the ANN-80 is mounted in a standard electrical box and wired correctly. Always disconnect power before starting installation to prevent damage or electrical hazards.

Mounting the ANN-80 Annunciator

Mount the ANN-80 in a standard single-gang electrical box to ensure proper fit and secure installation. Verify the annunciator is level and aligned with surrounding surfaces for a professional appearance. Use the provided mounting hardware to fasten the unit securely. Ensure all connections are made carefully to avoid damage. The compact design allows for easy installation in various locations, making it suitable for both new and existing fire alarm systems. Always follow the manufacturer’s guidelines for optimal performance and safety.

Wiring and Connectivity

Connect the ANN-80 to a compatible Fire Alarm Control Panel (FACP) using a two-wire serial interface via the ANN-Bus protocol. Ensure proper wiring to avoid damage or malfunction. Connect the positive and negative terminals to the power supply, maintaining the specified voltage range of 18-28 VDC. Refer to the FACP manual for specific wiring requirements. Secure all connections tightly and avoid reversing polarity. Turn off power before performing any wiring to ensure safety and prevent system issues. Proper connectivity ensures reliable communication and accurate system status display.

Programming the ANN-80 Annunciator

Program the ANN-80 to customize zones, points, and display settings, ensuring proper communication with the FACP. Follow detailed instructions for a seamless configuration experience.

Configuring Zones and Points

Configure zones and points to monitor specific areas and devices. Assign each zone to a unique FACP circuit and label points for clarity. The FACP manual provides step-by-step guidance for mapping zones and points to the ANN-80. Ensure all devices are correctly assigned to their respective zones for accurate monitoring. This setup allows the ANN-80 to display precise information during alarms or troubles, aiding in quick identification and resolution of issues. Proper configuration is essential for reliable system performance and clear communication of fire safety statuses.

Setting Up the Annunciator’s Display

Configure the ANN-80’s display settings to optimize visibility and clarity. Adjust brightness and contrast for ideal readability in various lighting conditions. Use the menu to customize text alignment, font size, and scroll speed. Enable or disable the backlight based on environmental needs. Program custom messages for zones and points to enhance identification. Ensure the display accurately reflects FACP statuses, including alarms, troubles, and supervisory conditions. Test the display after configuration to confirm proper operation and legibility.

Operation and Functionality

The ANN-80 operates as a remote annunciator, providing clear LCD display of system statuses, alarms, and zone information, ensuring effective monitoring and response to fire conditions.

Understanding the LCD Display

The ANN-80 features a compact, backlit 80-character LCD display that provides clear, real-time information about system status, zones, and points. Designed for easy readability, it mimics the Fire Alarm Control Panel (FACP) display, showing device types, independent point alarms, trouble conditions, supervisory zones, and custom alpha messages. The display is available in red backlighting, ensuring visibility in various lighting conditions. This feature enhances situational awareness, allowing users to quickly interpret critical fire safety information.

Interpreting System Status and Alarms

The ANN-80 LCD display provides real-time status updates, including active alarms, trouble conditions, and supervisory zones. Alarms are prominently displayed in red, while trouble or supervisory conditions appear in yellow. The system offers detailed English-language text for device types, independent point alarms, and custom alpha messages. Understanding these indicators enables quick identification and resolution of issues. The display’s clarity ensures that users can interpret critical information effortlessly, supporting timely and effective responses to fire safety events. This feature is essential for maintaining system reliability and user confidence.

Maintenance and Troubleshooting

Perform regular checks on the ANN-80 display and connections to ensure optimal functionality. Refer to the manual for troubleshooting common issues like error messages or connectivity problems.

Regular Maintenance Tips

Regularly clean the ANN-80’s LCD display with a soft, dry cloth to maintain visibility. Inspect all wiring connections for integrity and tightness. Power cycle the device monthly to reset internal components. Check for firmware updates and install them as needed. Replace backup batteries annually or as specified. Ensure the annunciator is mounted securely and level. Test all zones and points quarterly to confirm proper operation. Document maintenance activities for future reference. Address any unusual behavior promptly to prevent system downtime.

Common Issues and Solutions

Common issues with the FireLite ANN-80 include loss of power, dim or inoperable display, or communication errors with the FACP. For power issues, check the wiring and ensure the annunciator is receiving 18-28 VDC. If the display is dim, adjust the backlight settings or replace the backlight if faulty. Communication errors may require resetting the ANN-Bus connection or updating firmware. For zones showing incorrect status, verify zone configurations in the FACP. If alarms persist unnecessarily, check for faulty sensors or programming errors. Always refer to the manual for detailed troubleshooting steps.

Technical Specifications

The FireLite ANN-80 features an 80-character backlit LCD display, operating on 18-28 VDC with a 40mA current draw. It is designed for compatibility with Fire-Lite FACPs and utilizes the ANN-Bus interface for seamless communication and control.

Hardware and Software Details

The FireLite ANN-80 features a compact, backlit LCD display with 20x, providing clear visibility of system status and alarms. It operates on 18-28 VDC with a maximum current draw of 40mA. The device communicates via the ANN-Bus interface, ensuring compatibility with Fire-Lite FACPs like the MS-9200UDLS. Firmware updates are supported through the ANN-Bus connection. The annunciator’s hardware includes a red backlit display for optimal readability, while its software enables detailed point information and custom messaging. It is designed to integrate seamlessly with Honeywell’s fire safety ecosystem.

Additional Resources

Access the full FireLite ANN-80 manual online as a downloadable PDF. Visit Honeywell’s official website for additional guides, or contact their support team for assistance.

Downloading the Full Manual

The complete FireLite ANN-80 user manual is available for download as a PDF from Honeywell’s official website. Visit their resource section or use the direct link: FireLite ANN-80 Manual. This document provides detailed installation, programming, and operational guidance. Additional resources, including product datasheets and technical guides, can also be found on Fire Alarm Resources. Ensure you reference the official sources for the most accurate and up-to-date information.

Contact Information for Support

For technical assistance, contact Honeywell Fire-Lite Alarms at One Fire-Lite Place, Northford, CT 06472-1653. Call 203-484-7161 for general inquiries or 203-484-7118 for fax. Visit their official website at www.firelite.com for support resources. For specific ANN-80 support, refer to the product installation document or reach out to their customer service team for troubleshooting and maintenance guidance. Ensure all queries are directed to authorized support channels for accurate assistance.

Leave a Reply